Aanbieding!

Doepke 09932127: Differentiëel automaat 32A 0,030A 1P+N C – Residual current operated circuit-breaker with integral overcurrent protection, one-pole+N, 32 A, 0,03 A, C-Characteristic, Type A

Beschikbaarheid:

Levertijd +/- 5 werkdagen


 85,18  141,97 (incl BTW)

Levertijd +/- 5 werkdagen

Doepke 09932127: Differentiëel automaat 32A 0,030A 1P+N C – Residual current operated circuit-breaker with integral overcurrent protection, one-pole+N, 32 A, 0,03 A, C-Characteristic, Type A

Function:

RCBOs combine residual current and miniature circuit-breakers in a single device (RCBO). They protect people against residual currents and systems against short-circuit and overload. Switches from series DRCBO 3 are independent of the mains voltage and have a high rated switching capacity. Separate displays enable a quick overview of the current operating conditions. DRCBO 3 can be conveniently installed and removed. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches with tripping characteristic C are optimised for electric circuits with high inrush or peak currents. Standard switches are designed for electric circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.

Features:

tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, green/red switching position indicator, residual current tripping indicator, Strain-relief clamps with protection against wires being lodged behind them and wide terminal cross-section range for rail and line wiring on both connection sides, Use of conventional wiring rails possible, Neutral conductor right, tri-stable snap-in slider for easy mounting and removal, high electromagnetic compatibility (immunity to interference for industrial applications)

Mounting method:

quick fastening to mounting rail, any installation position, supply as desired

Applications:

Protection of circuits in residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCCB/MCBs can be set to switch off in the event of a second earth fault, Not permitted for use in systems with TN-C networks; not permitted for protecting circuits in which the power electronics equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50/60 Hz.

 